DLT-6405
PVC Membrane Material

A PVC membrane with a lacquer finish for stadium roof and canopy projects.

Material Data
Weight
1250gsm
Width
3m

TECHNICAL DATASHEET

DLT-6405 | Material specifications
Weight1250gsm
Width3m
Thickness0.98mm
Tensile strength — warp6200 N
Tensile strength — weft6000 N
Tear strength — warp800 N
Tear strength — weft800 N
Surface treatmentPVDF / Acrylic
Flame-retardant gradeB1
Listed applicationFrame structure / Membrane structure

Product Features

  • PVDF / acrylic surface finishThe PVC membrane has a listed lacquer finish. Confirm the finish required for the order.
  • Flame-retardant gradeRequest the test report for the grade specified on the project.

Material specification

DLT-6405 is a 1250gsm PVC membrane, 3m wide and 0.98mm thick, with a PVDF / Acrylic surface. Tensile strength is 6200 / 6000 N (warp / weft); tear strength is 800 / 800 N (warp / weft). The listed flame-retardant grade is B1. Request the relevant test report for project review.

Project sampling

Confirm the required finish, panel layout and material tests against the project specification before ordering a sample.

Options to specify

Anti-UV, anti-mold, anti-wicking, cold-resistant and flame-retardant options are listed for this range. Agree the selected option and supporting test evidence; these options are not a standard certification for every order.

Application requirements — Parking Canopies

Specify the covered span, panel dimensions, support arrangement, installed tension and exposure. Review tensile and tear properties, coating adhesion, seam performance and the reinforcement around edges and attachment points. Set weathering, cleaning and fire-behaviour requirements around the finished structure and destination; the fabric data sheet does not establish structural wind or snow capacity.

DLT-6405 material reference: Weight: 1250gsm · Thickness: 0.98mm · Width: 3m

Discuss the application.

Confirm the required finish, panel layout and material tests against the project specification before ordering a sample.

Read a model-specific technical data sheet

Select a model from the directory to see its photographs, construction, dimensions and available test information. Values for one model should not be copied to another grade in the same family. The complete technical table keeps the published fields together.

For a quotation, identify the model and configuration required for the finished product. Include quantity, width and test criteria, then use RFQ101 to prepare the enquiry.