DLT-5304
Blower Connector Fabric
A polyester-reinforced PVC film composite for flexible blower connections.
- Weight
- 600g(±10g)/sqm
- Width
- 1.02m-3.2m
Product images
TECHNICAL DATASHEET
| Structure: | PVC film+Polyester base fabric+PVC film |
|---|---|
| Base fabric: | 1000D |
| Width: | 1.02m-3.2m |
| Weight: | 600g(±10g)/sqm |
| Colour: | Yellow/Black or customized |
| Flame retardant: | Self-extinguish |
| Tensile strength: | 1650/1490(N/5cm) |
| Tearing strength: | 350/290(N/5cm) |
| Peeling off strength: | 80(N/5cm) |
| Suitable temperature: | -20° to +70° |
| Package: | Paper tube + Craft paper |
| Meter per roll: | 30m-506m |
APPLICATIONS:
Product Features
- AntistaticHelps manage electrostatic charge build-up in the fabric, giving manufacturers a material option for assemblies with specified static-control requirements.
- Flame retardantA flame-retardant formulation for fabricators supplying projects with defined fire-behaviour requirements. Select the grade around the test method required for the finished application.
Reinforcement Behind the Flexible Faces
The stated three-part construction of DLT-5304 uses PVC film faces around a 1000D polyester base. Its 600gsm nominal mass is a finished-sheet value rather than a yarn weight. For a connector sample, inspect the selected face and the textile bond as well as the proposed edge construction. The precise production route is not listed, so the material should not be described as knife-coated without confirmation.
Connector Assembly Needs Its Own Review
Blower connectors introduce repeated movement and fastening loads that are not represented by a single sheet-strength figure. Use DLT-5304 in a trial assembly with the intended seam, flange attachment and reinforcement arrangement. Define the air temperature, movement and pressure conditions for the application. Self-extinguishing wording in the source needs supporting evidence where a fire requirement applies; it does not establish a complete connector rating.
Application requirements — Ventilation Ducts
Specify duct diameter and section length, positive or negative operating pressure, airflow conditions, connector design and suspension spacing. Review tensile and tear properties, coating adhesion, seam integrity and leakage in the assembled duct. Identify any required fire behaviour, static-control and temperature criteria for the installation; these must be checked against the selected configuration and applicable test evidence. Another application is dog play and agility tunnels. For these, specify the tunnel diameter, length, support hoops, anchoring and cleaning needs; assess the seams and the finished tunnel around the intended dogs and setting.
Common Finished Ventilation Duct Specifications
| Specification | Typical Configuration |
|---|---|
| Duct Construction | Layflat blowing duct; spiral-reinforced duct for extraction or bends |
| Layflat Diameter Examples | 300–3000 mm nominal diameter |
| Layflat Section Lengths | 5, 10, 20, 30 or 50 m sections |
| Reinforced Duct Examples | 250–1400 mm diameter; 5 or 10 m sections |
| Section Connections | Zip, hook-and-loop, reinforced eyelet or end-ring connections |
| Suspension | Welded suspension fins or reinforced patches on layflat ducts; rings on reinforced ducts |
| Seams And Attachment Areas | Welded body seams, sealed connection sleeves and reinforced suspension areas |
| Operating Duty | Define blowing or extraction, fan airflow, static pressure and installed length together |
Duct Construction And Connections
A welded top fin carries the suspension points. The end sleeve seals the connection between sections.
The reinforcement supports the duct wall during extraction. Wire specification and pitch follow the suction duty.
Product Videos 3 videos
Antistatic Tarpaulin: Material Demonstration
Production & Material Footage
Discuss the application.
For blower connector fabric rolls, send the connection dimensions, movement range and air-service conditions.
Blower Connector Fabric: Building a Flexible Connection
DLT-5304 is a 600gsm PVC composite, with a stated ±10gsm tolerance, built around a 1000D polyester base. Its documented layers are PVC film, polyester fabric and PVC film. The reinforced sheet is the starting material for a fabricated connection; flange details, connector geometry and fastening hardware are added during assembly.
The polyester base and PVC faces contribute different aspects of the construction. Yarn size describes the reinforcement, while the finished mass includes both reinforcement and covering material. The bond holding those layers together needs to be considered alongside tensile and tear behaviour. None of those properties alone establishes fatigue life under repeated connector movement. The model data does not specify a particular coating or laminating route.
Yellow and black are listed with custom colours, and the available width range is stated as 1.02m to 3.2m. The source describes the material as self-extinguishing. If a project requires a particular fire classification, supporting documentation is needed for the selected version and intended use. An antistatic rating should not be assumed because it is not included in this model’s listed data.
A proposed flexible blower connector should be reviewed with its working dimensions, displacement and air conditions. Fabrication trials can assess the actual seams and the edges held at the connections. Check how those edges are reinforced and secured, rather than relying on the roll material’s peeling value. Equipment movement, pressure and installation loads belong in the assembled connector’s engineering review.