Our PTFE fabrics combine an EC6 woven fiberglass base with a multilayer PTFE coating. This range brings closed membrane fabrics for tensile roofs and canopies together with open mesh for facade screens and architectural shading. Start with the coverage and shading needs of the structure, then choose the fabric construction.

The eight membrane grades weigh 1000–1800gsm, with roll widths of 3–3.8m and thicknesses of 0.6–1.2mm. The two mesh grades weigh 700gsm and come in widths of 2–4m. Compare each model’s dimensions and warp and weft tensile values with the panel design, seam layout and fabrication equipment.

The listed fabrics have a matte surface and are beige before bleaching to white. Seam fabrication uses FEP welding strip or tape; agree the joining process and validate trial seams on the actual material before production. PTFE grades are listed as A1 for fire performance. Confirm the matching test report and supplied configuration for your project; a material classification does not approve the complete installed structure.

PTFE Fiberglass Membrane

Material overview

Watch on YouTube

PVC membrane or PTFE fiberglass membrane?

Compare the reinforcement and coating first, then select a grade for the proposed roof or canopy. Fire performance and service life depend on the supplied material and project conditions.

White PVC membrane fabric with polyester reinforcement

PVC membrane

Polyester reinforcement

Beige PTFE-coated fiberglass material surface

PTFE fiberglass membrane

Woven fiberglass reinforcement

Selection pointPVC membranePTFE fiberglass membrane
ConstructionPVC-coated polyester reinforcementPTFE-coated woven fiberglass
CoatingPVC coating; surface finish depends on the gradeMultilayer PTFE coating
Surface finishAcrylic or PVDF finish options; confirm the selected gradeMatte surface; listed grades are beige and become white after bleaching
Cleaning and exposureAgree the finish, exposure and cleaning requirementsLow-surface-energy PTFE coating; plan cleaning for the installation and exposure
Service-life planningConfirm the grade, environment and maintenance conditionsListed grade reference: 25 years, subject to project conditions
Fire performanceConfirm the test report for the supplied grade and configurationA1; confirm the test report for the supplied configuration

Swipe or scroll horizontally to compare all columns.

Membrane or open mesh?

Choose the covering or shading function before comparing weight and strength. The two mesh grades list 25–35% openness and 45% light transmission at 550nm. Openness describes the open area of the weave; light transmission is a separate optical measure.

PTFE-coated fiberglass membrane surface

PTFE membrane

Closed membrane surface

Open weave of PTFE-coated fiberglass mesh

PTFE mesh

Open weave for facade shading

Selection pointPTFE membranePTFE mesh
Material formCoated fiberglass membraneOpen-mesh coated fiberglass
Typical useTensile roofs, canopies and architectural panelsFacade screens and architectural shading
Available grades8 membrane grades2 mesh grades
Weight range1000–1800gsm700gsm
Roll width3–3.8m2–4m
OpennessSelect by the membrane specification25–35% for the listed mesh grades

Swipe or scroll horizontally to compare all columns.

Browse all 10 PTFE materials ↓

FEP strip and seam fabrication

The PTFE fabrication process uses 0.8mm FEP welding strip. The two processes below use different controls; select the equipment and seam process with the fabric grade.

ProcessEquipmentCurrent or temperatureCycle time or travel speed
Dedicated high-frequency weldingDedicated high-frequency welding machine1.0–1.2A8–10sec
Hot-air weldingHot-air welding machine550°C4–5m/min

Swipe or scroll horizontally to compare all columns.

Product datasheets also list hot-bar welding with FEP welding tape. These process settings are for fabrication discussion; confirm equipment suitability and validate trial seams on the actual material before production. Provide the panel drawings, seam layout, grade and quantity with your enquiry.

10 materials

Roll materials for fabrication
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ5500

PTFE-Coated Fiberglass Membrane

Weight
1000gsm
Width
3-3.8m
Thickness
0.6mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ6500

PTFE-Coated Fiberglass Membrane

Weight
1150gsm
Width
3-3.8m
Thickness
0.65mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ7500

PTFE-Coated Fiberglass Membrane

Weight
1450gsm
Width
3-3.8m
Thickness
0.8mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ8000

PTFE-Coated Fiberglass Membrane

Weight
1400gsm
Width
3-3.8m
Thickness
1.0mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ9000

PTFE-Coated Fiberglass Membrane

Weight
1600gsm
Width
3-3.8m
Thickness
0.85mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ11000

PTFE-Coated Fiberglass Membrane

Weight
1800gsm
Width
3-3.8m
Thickness
1.2mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ800

PTFE-Coated Fiberglass Membrane

Weight
1500gsm
Width
3-3.8m
Thickness
0.9mm
View Details ↗
PTFE-Coated Fiberglass Membrane material surface

DLT-PJ5800S

PTFE-Coated Fiberglass Membrane

Weight
1000gsm
Width
3-3.8m
Thickness
0.6mm
View Details ↗
PTFE-Coated Fiberglass Mesh material surface

DLT-PJM5000

PTFE-Coated Fiberglass Mesh

Weight
700gsm
Width
2-4m
Thickness
0.6mm
View Details ↗