DLT-5207
PVC Vinyl Tarp for Concrete Curing Covers

A polyester-reinforced PVC laminate for roof panels on tents and temporary shelters.

Material Data
Weight
850gsm
Width
1.05-3.2m

TECHNICAL DATASHEET

PVC tent fabric | DuraTarps DLT-5207
Technology:Lamination / Coating
Structure:PVC film+polyester base fabric+PVC film / 3 layers laminated
Base fabric:1000D 23*23
Thickness:0.65mm
Weight:850gsm
Width:1.05-3.2m
Roll length:50m
Surface:Glossy/Matte
Blockout:Extra blockout layer available
Colour:Customized
Temperature:-20~+70(°C)
FR certification:Customized B1, B2, M1, M2, NFPA701, DIN75200;
Packing:Paper tube+PE film+Craft paper
MOQ:3000yards for customization/ 100yards for in-stock

Product Features

  • Flame retardantOptionalAvailable as an optional configuration. A flame-retardant formulation for fabricators supplying projects with defined fire-behaviour requirements. Select the grade around the test method required for the finished application.
  • BlockoutOptionalAvailable as an optional configuration. Restricts light passing through the fabric for roof, curtain or cover panels that need an opaque finish and greater control of the light behind the surface.

Area Weight and Internal Construction

At 850gsm, DLT-5207 includes the mass of its PVC films and polyester base. The 1000D and 23×23 entries identify the reinforcement more specifically. Thickness is listed separately at 0.65mm. Read these values together rather than substituting one for another. Film adhesion and the required mechanical properties should be assessed with their own methods when preparing a material specification for fabrication.

Laminated Sheet and Site Use

DLT-5207 lists a laminated PVC-film structure with glossy or matte faces. The chosen surface and any added blockout layer should be fixed on the approved sample. Joining produces the finished cover from the original laminate, so a seam trial addresses a different interface from the film-to-fabric bond. A proposed curing-cover design also needs application-specific review of contact, handling and moisture-control requirements.

Application requirements — Tent Roofs & Sidewalls

Specify the covered span, panel dimensions, support arrangement, installed tension and exposure. Review tensile and tear properties, coating adhesion, seam performance and the reinforcement around edges and attachment points. Set weathering, cleaning and fire-behaviour requirements around the finished structure and destination; the fabric data sheet does not establish structural wind or snow capacity.

Finished Frame-Tent Configurations

Roof covers are made to the tent frame and its bay spacing. Overall tent dimensions do not equal the flat cutting dimensions of a roof panel.

Finished-Product Configuration Examples
SpecificationConfiguration
Small Frame-Tent Span Examples4 m, 5 m, 8 m or 10 m
Bay Spacing Examples3 m or 5 m, depending on the frame series
Overall LengthRepeated bays; confirm the minimum assembly and any end-bay changes for the selected frame
Side Height ExamplesApproximately 2.3 m or 3 m in modular event-tent configurations
Roof ArrangementSeparate roof, gable and sidewall panels fitted to the frame geometry
Roof-Edge ConnectionKeder edges retained in frame channels; bead and channel dimensions must match
Sidewall ArrangementDivided wall panels, with ground bars or the selected frame system's bottom restraint
Site DesignConfirm frame anchoring, drainage and the complete structure's wind and snow requirements before fabrication

Construction Details

Keder Edge And Frame Channel

The fabric edge carries a bead that slides into the frame channel. Specify the finished bead diameter and edge construction from the actual profile drawing.

Roof Panel And Bay Layout

A roof panel follows the pitch between frame members. Its finished length includes the attachment and tensioning details; fabric-roll width alone cannot define the cover size.

Discuss the application.

For PVC vinyl tarp rolls, include the proposed cover layout and the contact and moisture-control requirements for the concrete-curing project.

PVC Vinyl Tarp: Reading a Reinforced Sheet Specification

DLT-5207 is PVC vinyl tarp material made with PVC films on either side of a polyester base. The reinforcement is listed as 1000D with a 23×23 construction. The finished sheet is specified at 850gsm and 0.65mm thick. The continuous PVC faces and textile core together form the material handled by the fabricator.

The catalogue identifies lamination/coating technology and a three-layer laminated structure. This supports a film-and-fabric construction description, without fixing a particular coating line. When evaluating a sample, distinguish surface condition from the internal bond and reinforcing fabric. Added sheet mass can come from the PVC as well as the textile, so it does not provide a complete measure of strength.

Glossy and matte surfaces, custom colours and an extra blockout layer are listed. For a proposed concrete-curing cover, select the actual material configuration before checking its behaviour in contact with the intended site conditions. The sheet specification alone does not establish a curing regime or a measured moisture-retention result. Those requirements should be agreed for the proposed application and checked with suitable evidence.

Rolls are listed at 50m long and 1.05m to 3.2m wide. Cover layout needs allowances for joins, edges and the placement of any handling details. Evaluate representative seams using the chosen surface. The finished cover can then be reviewed against the project requirements, including the way it is placed, moved and stored between uses.